Damalini ABÅbäcksgatan 6B431 67 Mölndal, SwedenTel +46 31 708 63 00Fax +46 31 708 63 50e-mail: [email protected]© 2005 Damalini AB. Cha
MEASUREMENT PROGRAMSMeasurement programs configurationsThese pages describe which programs and functions the Display unit D279has for the different me
MEASUREMENT PROGRAMSXXXXXXXXXXXBTA digital - For measurement and alignment of pulleys.Values - This program displays the values from the detector in l
MEASUREMENT PROGRAMSD525D600D630D650D660D670D800XXXXXXD505D450Half-Circle - Measurement values are taken in the 9, 6 and 3 o’clock positions.Allows va
GETTING STARTEDManualThis manual describes in order:The hardware parts:Technical specifications and functions.Handling the display unit:Settings, butt
GETTING STARTEDThe measurement systemIn the following way you connect the system tolearn how to handle it. For the description of eachlaser, measuring
GETTING STARTED10. After the measurement is finished you can dothe following; save the result in the display unit, ifyou have a printer; connect this
ASystem A. SystemComplete systems ... A2Complete systems ... A
COMPLETE SYSTEMSA2D200 Sheave/Pulley alignment system1 Display unit D279 with 27 programs/functions1 Cable with push-pull connectors1 Detector unit D1
COMPLETE SYSTEMSAA3D525 Shaft Alignment systemD600 Machine (Basic)1 Display unit D279 with 27 programs/functions2 Cables with push-pull connectors (2m
APPLICATION EXAMPLES FOR EASY-LASER®
COMPLETE SYSTEMSA4D660 Turbine system1 Display unit D279 with 27 programs/functions2 Cables with push-pull connectors1 Laser transmitter D75 with offs
DISPLAY UNIT D279AA5Display unit D279: Different number ofmeasurement programs depending on whichsystem the display unit is included in (thesoftware c
SPINNING LASER D23A6TECHNICAL SPECIFICATIONSLaser diode < 1 mW Class 2Laser wavelength 635–670 nmLaser beam diameter 6 mm [1/4”] at apertureRange o
SWIVELLING LASER D22Laser transmitter with swivelling head for 360osweep of the laser beam (Alt. 1). The sweep canbe leveled to a horizontal or verti
SWIVELLING LASER D22: dimensionsTECHNICAL SPECIFICATIONSLaser diode < 1 mW Class 2Laser wavelength 635–670 nmLaser beam diameter 6 mm [1/4”] at ape
LASER D22, D23: calibrating the vialsA9Here we describe how you calibrate the vialson the D22 and D23. This is normally done atdelivery, but can be re
LASER D22, D23: calibrating the vialsA10When calibrating the single vial on laser-transmitter D22, the sweep of the laser can beused. Place the detect
SPINDLE LASER D146AA11Laser apertureBattery cap(use a coin to lock)Alt. 1 Alt. 2Laser adjustmentscrewsLaserapertureOn / OffMounting plate andclamping
A12SPINDLE LASER D146: technical specificationsTECHNICAL SPECIFICATIONSHousing material Anodized aluminumLaser diode < 1mW, Class 2Measurement dist
The laser transmitter D75 is used formeasurement of straightness and spindledirection. At the sides M6-threads allowalternative mounting possibilities
ABCDEFSystemHandlingProgramsApplicationsBasicsAppendix
TECHNICAL SPECIFICATIONSLaser diode < 1 mW Class 2Laser wavelength 635–670 nmBeam diameter 6 mm [1/4”] at apertureMeasurement distance 40 meter [13
MEASURING UNITS PSD 18x18mmDetector apertureSliding targetVialsConnectionsMeasuring units with PSD detector (18x18 mm),thermal sensor, electronic 360°
TECHNICAL SPECIFICATIONSDetector type 1-axis alt. 2-axis PSDDetector size 18x18 mm [3/4”x3/4”]Linearity Better than 1%Laser diode < 1 mW Class 2Las
MEASURING UNITS PSD 10x10mmMeasuring units with PSD detector (10x10 mm),and laser diode in one housing. The housing hasa number of threads and mountin
TECHNICAL SPECIFICATIONSDetector type 1-axis PSDDetector size 10x10 mm [3/8”x3/8”]Linearity Better than 1%Laser diode < 1 mW Class 2Laser wavelengt
DETECTOR D5Detector apertureSliding targetVialsConnections on two sidesDetector that can read the position of alaserbeam. Built-in electronic 360° inc
A20DETECTOR D157Front BackFacing towards the laser, movements of thedetector to the right will give positive H-valuesand moving upwards will give posi
DETECTOR D6AA21Detector apertureConnections on two sidesWith SpinLaserTechnology™. Detector that canread the position of a rotating laser beam from th
A22LARGE TARGET BASE LINE TRIPODTarget for datum line finding/setting. For useon floor or at magnet base with rods. Instead ofa target, a detector can
90O ANGULAR PRISM D46Tilting plateHorizontal tiltVertical tiltFine turning screwLocking knob for fine turningVertical adjustmentSliding way for transv
TABLE OF CONTENTS A. SystemComplete systems ... A2Complete systems ...
90O ANGULAR PRISM: calibration, technical specificationsParallel alignment1. Switch the prism away to let the beam hit the target.2. Slide the prism t
SHAFT BRACKETSThin shaft brackets.W=Width: 12 mm [1/2”]. With chain and thin toolfor chain tensioning.Standard Shaft brackets with chains.For shafts Ø
SLIDING BRACKETSBrackets for use when turning ofshafts is not possible.To be used with standard chainsor magnets and with or withoutturnable head depe
MAGNET BASE D45TECHNICAL SPECIFICATIONSDimensions WxHxD 50x80x60 mm [2”x3 1/8”x2 3/8”]Weight 1200 g [2.8 lbs]Holding power 800 NMagnet base with turna
A28ACCESSORY BRACKETSLaser bracket (D75)For mounting on standard rods.Side support for detector D5For straightness measurement.Laser bracket (D75)For
CARDAN BRACKETCardan bracket setFor measurement and alignment of offset mountedmachines. Largest offset 900 mm [3´].2 Magnetic bases2 Bracket arms1 Br
TURBINE; fixtures etc.A30Note!On special request we manufacture a measurement systemfor turbines where the axial flange and the center line of theturb
LINEBORE SYSTEM: coordinate hubAA31Coordinate hub with three arms and magnetsfor mounting and parallel movement (adjustmentto centre) of the laser tra
LINEBORE SYSTEM: detectorDetector with offset hub. Built-in electronic 360°inclinometer. Three adjustable arms for placing thedetector in circular mea
EXTRUDER: fixtures etc.AA33Magnets (x3)Bracket for laser D75Adapter plates (two) for Detector D157.Manufactured to actual tubediameter at order time.L
Program 16, Offset and Angle ... C22Program 17, Values ...C24Program 18, Machine train
BTA DIGITAL: laser transmitter D164A34Laser transmitter with rotating beam(180° aperture). Turnable arm with movableattachment magnets. Battery operat
BTA DIGITAL; detector unit D162AA35Marked centre lineDetector housing, turnable + 135°(two pcs.)Detector armDetector aperture(two pcs.)Detector unit w
PRINTER KYOLINE BATThermal printer for Easy-Laser® systems.When the power is turned on, the printer performs manyinternal tests and initializations. W
VIBROMETER PROBE D283AA37Vibrometer probe D283: To use together withthe Vibrometer program in display unit D279.TECHNICAL SPECIFICATIONS(Instrument/So
A38LASER TRANSMITTER D22, D23 and D75: tilting screwsThe tilting screws on the levelling table of theD22 and D23 lasertransmitter, and on the D75trans
DECLARATION OF CONFORMITYDamalini AB declares that the Easy-Laser® product range is manufactured in conformity withnational and international regulati
SAFETY PRECAUTIONSEasy-Laser® is a laser instrument in laser class IIwith an output power less than 1 mW, which onlyrequires the following safety prec
DAMALINI ABEasy-Laser®: measurement equipment foryour needsDamalini develops and manufactures Easy-Laser®for measurement and alignment of machinery a
UPGRADABILITYLasersSystems and partsThe Easy-Laser® systems are designed to grow as the needsincrease. Measurement systems D450 and D505 have as stan-